ADC ADView 2 Modular Diagnostic Station

American Diagnostic Corporation

  • $900.00
    Unit price per 
  • Save $230
Shipping calculated at checkout.

Only 40 left!


ADC ADView 2 Modular Diagnostic Station

Description

The ADC ADView 2 Modular Diagnostic Station includes a rechargeable lithium-ion battery, U.S. power cord, 10-foot length of tubing, Adult Plus and Large Adult Plus cuffs, Mini-USB to USB cable, a Quick Start Guide, and a Quick Reference Guide.

The Temperature Module can be added and includes an oral/axillary probe and well (blue) and a box of 20 probe covers.

A Pulse Oximetry Module can also be added and is available with a ChipOx Nellcor Compatible SpO2 Module or a Masimo SET SpO2 Module that includes a reusable adult finger sensor and an eight foot extension cable.

Warranty: 3 Years 

 

  • Configurations

    ADC ADView 2 Modular Diagnostic Station Configurations

  • ADView 2 Blood Pressure Base Unit (#9005BP).
  • ADView 2 Blood Pressure Base Unit with Temperature Module (#9005BPTO).
  • ADView 2 Blood Pressure Base Unit with ChipOx Nellcor Compatible SpO2 Module (#9005BPS).
  • ADView 2 Blood Pressure Base Unit with ChipOx Nellcor Compatible SpO2 Module and Temperature Module (#9005BPSTO).
  • ADView 2 Blood Pressure Base Unit with Masimo SET SpO2 Module (#9005BPSM).
  • ADView 2 Blood Pressure Base Unit with Masimo SET SpO2 Module and Temperature Module (#9005BPSMTO
  • Specifications

ADC ADView 2 Modular Diagnostic Station Specifications

  • Conditions for Use: 10 degrees C (50 degrees F) to 40 degrees C (104 degrees F) 15 - 90% RH non-condensing - 700 kPa - 1060 kPa.
    • Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41 degrees C (41.6 degrees C highest recorded) on a patient-applied part.
    • It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38 degrees C or below.
  • Storage: -20 degrees C (-4 degrees F) to 55 degrees C (149 degrees F) 15 - 90% RH non-condensing - 500 kPa - 1060 kPa.
    • Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
  • Power: Internal power supply.
    • Input: 100-240 VAC @ 1.5A max, 50-60 Hz.
    • Output: +9VDC @ 5A IEC 320 type input connector.
  • Battery:
    • Type: 7.2v, 6600mAh Internal Lithium-Ion battery.
    • Run Time (full charge): ~20 hrs* / 200 BP cycles.
    • Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg.
    • *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner.
  • Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
  • Safety Systems: Independent hardware over-pressure circuit and redundant software over-pressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
  • Dimensions (without thermometer option): 8" (215 mm) H x 6.75" (190 mm) W x 5.2" (140 mm) D.
  • Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013.
  • Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE.
  • Ingress of Liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
  • Blood Pressure Range:
    • Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
    • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric).
    • Heart Rate: 30-220 BPM (beats per minute).
  • Blood Pressure Accuracy: Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (+/-5mmHg mean error with 8mmHg standard deviation).
  • Temperature Module Specifications:
    • Temperature Accuracy:
      • Quick Mode (Oral): +/- 0.3 degrees C.
      • Std. Mode (Aux/Recta): +/- 0.1 degrees C.
      • Direct Mode: +/- 0.1 degrees C.
    • Response Time:
      • Quick Mode: 4 sec.
      • Axillary/Rectal: 10-15 sec.
      • Direct Mode: 60 sec.
    • Resolution: 0.1 degrees C.
  • SpO2 Module Specifications:
    • Saturation Normal (no motion): 70-100%Arms +/- 2%.
    • Saturation Motion: N/A.
    • Low Perfusion: N/A.
    • Pulse Heart Rate: 20-300 BPM: +/-3 BPM.
    • Pulse Heart Rate w/motion: 20-300 BPM: +/-3 BPM

 


We Also Recommend


Customer Reviews

Based on 2 reviews Write a review